临邑输油站2008年建成的原油精密配输系统采用超声波流量计UFM3030,计量精确度极高,给临邑站的精密配输带来了极大便利,但对大管径、高输量的胜利油的计量精度较低。根据原油精密配输系统的工艺流程,介绍了超声波流量计的组成与测量原理,分析了在原油精密配输系统使用中超声波流量计UFM3030出现计量误差的原因。结果表明:UFM3030超声波流量计的精度与管输油品雷诺数有关,即超声波流量计的误差主要是油品、温度和输量(或管径)不同引起的。建议将胜利油给油泵出口汇管和鲁宁管道外输支管上换成完全不受雷诺数影响的五声道超声波流量计,以最大限度地避免当前的计量误差。
In the crude oil transportation system in Linyi Pump Station(built in 2008),UFM3030 ultrasonic flowmeter is used.Its high-precision measurement contributes greatly to the transportation in the pump station.However,the flowmeter shows low precision when measuring Shengli Crude which is transported via large-diameter high-throughput pipeline. According to the system process,the composition and principle of the ultrasonic flowmeter are introduced,and the errors occurred when UFM3030 is used in the system are analyzed.Results show that the accuracy of UFM3030 is related to the Reynolds number of crude oil.In other words,the errors of the flowmeter are primarily caused by oil,temperature and throughput(or diameter).Accordingly,it is suggested that,at the outlet manifold of oil-feed pump of Shengli Crude and the offtake line of Lu-Ning Oil Pipeline,the five-channel ultrasonic flowmeter is used,which is not affected by Reynolds number.In this way,the measurement errors may be minimized.
[1]赵名师,赵铭超,杨海鹏,等. 自动化控制在临邑输油站原油精密配输中的应用[J].石油工程建设, 2010, 36 (2):47-50.
ZHAO M S,ZHAO M C,YANG H P,et al. Application of automatic control in crude oil precise mixing transportation at linyi oil station[J].Petroleum Engineering Construction, 2010, 36 (2):47-50.
[2]王怀军,冷鑫宁,赵连科.原油精密配输控制系统的功能实现[J].化学工程与设计, 2009 (9):57-59.
WANG H J,LENG X N,ZHAO L K.Function realization of the crude oil precise mixing transpotation control system[J].Chemical Engineering & Equipment, 2009 (9):57-59.
[3]章瑞平,李国锋.超声波流量计在液体测量中的应用[J]. 廊坊师范学院学报, 2003, 19 (4): 98.
ZHANG R P,LI G F.The application of ultrasonic flowmeter in liquid transmission metering[J]. Journal of Langfang Teachers College, 2003, 19 (4): 98.
[4]陈亦文,邱公伟. 超声波流量计的原理、应用和发展[J]. 福建电脑, 2002 (9): 34.
CHEN Y W,QIU G W. The theory, application and development of ultrasonic flowmeter[J]. Fujian Computer, 2002 (9): 34.
[5]邱国胜,靳大全.多通道超声波流量计的测量原理及应用[J]. 科技与企业, 2012, 22: 362.
QIU G S,JIN D Q.Principle of measurement and application of multi-channel ultrasonicflowmeter[J]. Science and Technology Enterprise, 2012, 22: 362.
[6]周伟国,胡海军,金颖. 超声波流量计的应用与误差分析[J]. 煤气与热力, 2001, 21 (4):337-339.
ZHOU W G,HU H J,JIN Y. Application and uncertainty analysis of ultrasonic gas flowmetersin gas transmissionmetering[J]. Gas & Heat, 2001, 21 (4):337-339.
[7]牛朋恩,薄秀江,程浩.时差法超声波流量计原理及应用案例[J].自动化应用, 2011 (6):68-69.
NIU P E,BO X J,CHENG H.Principle and application cases of ultrasonic time difference flow meter[J].Automation Application, 2011 (6):68-69.
[8]杨淑银. 超声波流量计的误差分析及修正[J]. 黑龙江冶金,2004 (2):34-36.
YANG S Y. Uncertainty analysis and correction of ultrasonic flowmeter[J]. Heilongjiang Metallorgy,2004 (2):34-36.
[1]杨建昌,王萍,邓立三,等.气体超声波流量计在天然气计量中的应用[J].油气储运,2002,21(9):35.[doi:10.6047/j.issn.1000-8241.2002.09.011]
YANG Jianchang,WANG Ping.The Application of Ultrasonic Wave Flowmeter in the Metering of Natural Gas[J].Oil & Gas Storage and Transportation,2002,21(8):35.[doi:10.6047/j.issn.1000-8241.2002.09.011]
[2]闫向宏.超声波流量计的现状与展望[J].油气储运,1998,17(8):51.[doi:10.6047/j.issn.1000-8241.1998.08.019]
Yan Xianghong.Situation and prospect of ultrasonic flow meter[J].Oil & Gas Storage and Transportation,1998,17(8):51.[doi:10.6047/j.issn.1000-8241.1998.08.019]
[3]刘明亮 陈福林 吴斌 孟祥华.天然气气质组分变化对超声波流量计的影响[J].油气储运,2012,31(9):714.[doi:10.6047/j.issn.1000-8241.2012.09.019]
Liu Mingliang,Chen Fulin,Wu Bin,et al.Impact of quality components of natural gas on ultrasonic flowmeter[J].Oil & Gas Storage and Transportation,2012,31(8):714.[doi:10.6047/j.issn.1000-8241.2012.09.019]
[4]陈刚 郭祎 于涛 张磊 刘超. 兰郑长管道超声波流量计测量误差的修正[J].油气储运,2012,31(11):877.[doi:10.6047/j.issn.1000-8241.2012.11.021]
Chen Gang,Guo Yi,Yu Tao,et al.Correction of metering error for ultrasonic flowmeter in Lanzhou-Zhengzhou-Changsha Products Pipeline[J].Oil & Gas Storage and Transportation,2012,31(8):877.[doi:10.6047/j.issn.1000-8241.2012.11.021]
[5]王立坤,王洪超,熊敏,等.长距离输油管道泄漏监测技术分析及研究建议[J].油气储运,2014,33(11):1198.[doi:10.6047/j.issn.1000-8241.2014.11.010]
WANG Likun,WANG Hongchao,XIONG Min,et al.Analysis and proposal on leak detection of long-distance oil pipeline[J].Oil & Gas Storage and Transportation,2014,33(8):1198.[doi:10.6047/j.issn.1000-8241.2014.11.010]
[6]魏广锋,陈子鑫,刘雪亮,等.中乌输气管道超声波流量计远程诊断技术应用实践[J].油气储运,2014,33(7):794.[doi:10.6047/j.issn.1000-8241.2014.07.022]
WEI Guangfeng,CHEN Zixin,LIU Xueliang,et al.Remote diagnosis by ultrasonic flowmeter for China-Uzbekistan Gas Pipeline[J].Oil & Gas Storage and Transportation,2014,33(8):794.[doi:10.6047/j.issn.1000-8241.2014.07.022]
[7]田顺佳,戚有龙,冯春辉,等.不同整流器对超声波流量计计量的影响[J].油气储运,2021,40(07):780.[doi:10.6047/j.issn.1000-8241.2021.07.009]
TIAN Shunjia,QI Youlong,FENG Chunhui,et al.Influence law of different rectifiers on measurement of ultrasonic flowmeters[J].Oil & Gas Storage and Transportation,2021,40(8):780.[doi:10.6047/j.issn.1000-8241.2021.07.009]
收稿日期:2013-9-18;改回日期:2014-6-10。
作者简介:杨华,工程师,1981年生,2012年硕士毕业于中国石油大学(华东)油气储运工程专业,现主要从事输油生产管理工作。Tel:13685107650,Email:yanghua822114@163.com